Direct fired asphalt storage tanks
Direct-fired asphalt storage tanks
Asphalt products > Asphalt tanks > Direct-fired asphalt storage tanks > Temperature control

Temperature control
Temperature control is achieved by two temperature sensors and two controllers. One controller is the main asphalt temperature controller, the other is a backup high-temperature controller for safety. Both controllers control burner on/off functions. The burner fires into the fire tube or shuts off in response to the controllers to maintain the stored asphalt at set temperature. Heating is automatically shut off before the asphalt level drops below the top of the fire tube.

Standard burner for direct-fired asphalt tanks is an oil-fired, on/off burner. Low-high-low, low-high-off, and fully modulating burners are available. Burners fueled by natural gas or combination gas/oil are also available.

Temperature sensors in direct fired asphalt tank   Temperature controllers for direct fired asphalt tank
Temperature sensors and capillary tubes for temperature controllers. Dial thermometer provides confirmation. Controllers for setting the temperature of the tank.

 

Oil-fired on/off burner, standard on direct-fired asphalt tanks.
Burner and firetube assembly





Home | Profile | Products - Asphalt | Products - Industrial | Products - Concrete
Literature | Tec-Notes | Parts | Service | Employment | Contacts

Please contact Heatec, Inc. at
Phone (423) 821-5200 | Toll-Free (800) 235-5200 | Fax: (423) 821-7673
5200 Wilson Road | P.O. Box 72760 | Chattanooga, Tennessee 37410

©2007 Astec Industries, Inc. All Rights Reserved.
Legal Notice | Privacy Policy | Webmaster